Shopping security
The Honeywell 05704-A-0144 is a four-channel control card designed for the System 57 gas detection network. It provides centralized monitoring for up to four individual gas sensors, converting analog signals into actionable data for industrial safety systems. This module combines precision signal processing, robust fault detection, and user-friendly calibration in a compact, rack-mountable format.
Multi-Channel Gas Monitoring
Supports four independent sensor inputs, including catalytic bead (flammable) and 4–20 mA (toxic or oxygen) signals
Reduces system complexity and saves rack space
Advanced Alarm and Fault Logic
Provides three configurable alarm levels per channel (A1, A2, A3)
Dedicated fault detection for sensor failure, short circuit, or open circuit
Electronic adjustment of bridge balance and signal gain
Precision Signal Handling
Full-scale signal range: 15 mV to 300 mV
Electronic current adjustment from 90 to 315 mA in 1 mA increments
Maximum drive voltage: 10 V, maximum line resistance: 40 ohms at 200 mA
Initial measurement accuracy: ±1%
User-Friendly Interface and Calibration
Multi-segment backlit LCD for real-time gas readings, channel status, and analog bar display
One-person calibration supported via front panel or engineering tool
Industrial Reliability
EMI/RFI shielding for high-noise environments
Rack-mountable design compatible with all System 57 components
Maximum power consumption: 12.8 W (200 mA sensor current), typical 8.5 W
Industrial gas detection in refineries, chemical plants, and confined spaces
Multi-zone monitoring for flammable, toxic, or oxygen-deficient environments
Integration with System 57 racks and safety networks
| Feature | Specification |
|---|---|
| Model Number | 05704-A-0144 |
| Manufacturer | Honeywell |
| Channels | 4 |
| Sensor Type | Catalytic Bead or 4–20 mA |
| Display | Multi-character backlit LCD with Bar Graph |
| Current Drive | Electronic, 90–315 mA in 1 mA steps |
| Maximum Drive Voltage | 10 V |
| Full-Scale Signal | 15–300 mV |
| Bridge Imbalance | ±100 mV from center at 2 V bridge voltage |
| Fault Detection | Open Circuit, Short Circuit, Single Bead Failure |
| Power Consumption | 8.5 W typical, 12.8 W maximum |
| Mounting | System 57 Rack |
| Shipping Weight | 2 kg |
| Protection | Short Circuit and Open Circuit Protected |
Q: Can the 05704-A-0144 card handle both flammable and toxic sensors?
A: Yes, it is compatible with catalytic bead (flammable) and 4–20 mA (toxic or oxygen) sensors.
Q: How is the card calibrated?
A: Calibration can be performed by one technician using the front panel or an engineering tool, reducing downtime.
Q: What is the expected installation lead time?
A: Estimated lead time is 6–8 weeks from order confirmation.
Q: Can this card replace other System 57 modules?
A: Replacement is only recommended if the model and part number (05704-A-0144) match to ensure proper alarm and signal processing.
Ships within 48 hours · Estimated delivery Jul 12 - Jul 17
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order