20% OFF shipping at yvanlemoine-films.com on orders over $79 + up to 10% OFF products
yvanlemoine-films.com
home > ADV161-P50 Yokogawa Digital Input Module | New & Original Stock > ADV161-P50 Yokogawa Digital Input Module | New & Original Stock
download picture
ADV161-P50 Yokogawa Digital Input Module | New & Original StockYokogawa ADV161 P50 CENTUM Series Digital Input Module The Yokogawa ADV161 P50, also cataloged as the ADV161 Digital Input Module, operates as a dedicated hardware component for discrete signal acquisition within CENTUM VP CS network platforms. The module executes direct voltage and state monitoring of field contact switches, relays, and pushbutton inputs, transferring the synchronized binary status data to the central process control stations via the
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Yokogawa ADV161-P50 CENTUM Series Digital Input Module

The Yokogawa ADV161-P50, also cataloged as the ADV161 Digital Input Module, operates as a dedicated hardware component for discrete signal acquisition within CENTUM VP/CS network platforms. The module executes direct voltage and state monitoring of field contact switches, relays, and pushbutton inputs, transferring the synchronized binary status data to the central process control stations via the internal FIO backplane interface.

Suffix Breakdown & Model Matrix

Code Type Selection Detail
ADV161 Base Model Digital Input Module (64-Channel, Isolated)
-P Input Type Configured with pushbutton input functional parameters
5 Display & Ex Option Without status display; with no explosion protection
0 Feature Set Basic hardware type

Hardware Specifications

Parameter Specification
Model ADV161-P50
Brand Yokogawa
Origin Japan
Weight 0.30 kg (Net module weight), 2 kg (Shipping weight)
Dimensions 107.5 x 130 x 32.8 mm
Operating Temp 0 to +60 deg C
Power Consumption 550 mA at 5 VDC (Backplane supplied)
Rated Input Voltage 24 VDC (Sink/source)
ON Voltage Range 20 to 26.4 VDC
OFF Voltage 5 VDC or lower
Input Current 2.5 mA per channel (plus/minus 20 percent)
Isolation 2 kV AC (Input to system)

Process Control & Channel-to-Channel Isolation

The Yokogawa ADV161-P50 implements optical isolation rated at 2 kV AC between the high-density external field wiring terminals and the internal system logic circuitry. This multi-level signal isolation blocks common-mode voltage transients and industrial electromagnetic noise from penetrating the central processing unit backplane. Built-in digital filters eliminate contact bounce and false signaling variables, while the module diagnostics monitor internal circuitry health to flag maintenance warnings directly in the CENTUM VP environment.

Frequently Asked Questions

Q: What physical differences exist on the module faceplate due to the "5" option code?

A: The "5" digit indicates that this specific configuration lacks the individual channel LED status display matrix on the front panel. Loop verification must be executed via the system engineering workstation diagnostics rather than visual inspection of the hardware faceplate.

Q: How do the time constraints differ between standard status inputs and pushbutton inputs on this module?

A: Standard discrete inputs execute with an 8 ms response time. When handling momentary manual switch actions, the module requires a pushbutton signal duration of 20 ms or greater for accurate detection, operating up to a maximum cycle rate of 25 Hz.

Field Installation Guidelines

  • Baseplate Engagement and Retaining: Slide the module into its assigned slot on the FIO baseplate unit using the molded top and bottom alignment guides. Press firmly until the multi-pin connector latches with the backplane bus, then secure the module positioning using the standard mechanical retention screws.
  • High-Density Wiring Distribution: Connect the 64-channel field cabling using the matching high-density pressure-clamp terminal blocks or pre-fabricated KS1 interface cables. Group and lace the wire bundles neatly within the enclosure wire ways to alleviate mechanical strain on the module front connector.
  • Inductive Load Suppression: When routing discrete inputs from dry contacts on external mechanical relays or solenoids, enforce proper external diode or RC suppression networks at the field device. This setup stops high-voltage inductive kickback from breaking down the input channel-to-channel isolation over long-term continuous operation.

ADV161-P50 Yokogawa Digital Input Module | New & Original Stock

Item no : 94624760369
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Sep 19 - Sep 24

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Fire Engine
Fire Engine

US$ 28.00

Min. order: 1 piece

4.0 (25 reviews)

Sold : Login>>

Related Searches