Shopping security
Imagine setting out on a long voyage or an extended RV adventure, only to find your batteries underperforming because charging wasn't tailored to real-world conditions. The Newmar TP Temperature Probe steps in as your reliable solution, ensuring chargers adapt dynamically to battery temperature fluctuations. This smart accessory monitors ambient conditions around your batteries, allowing Phase Three chargers to adjust voltage output automatically for safer, more efficient charging cycles.
Crafted for rugged marine and recreational vehicle environments, the TP probe features a durable 25-foot cable that gives you flexibility in placement—whether mounting near house banks, engine starts, or auxiliary power systems. By providing precise temperature data, it prevents overcharging in hot climates or undercharging in cooler ones, extending battery lifespan and maximizing every amp-hour of capacity.
Engineered exclusively for Newmar's PT-32-30, PT-24-45F, and PT-24-95F Phase Three charger models, the TP probe integrates seamlessly without modifications. These chargers rely on the TP for advanced temperature compensation, distinguishing it from the TCS-12/24 sensor used in other models. Always verify your charger's model to ensure optimal performance—using the wrong sensor could lead to inaccurate readings and suboptimal charging.
In marine applications, where humidity and salt air challenge electronics, this probe's robust construction maintains accuracy. RV enthusiasts appreciate its role in multi-bank setups, keeping thruster batteries, inverters, and lighting systems primed for action.
Unlike basic thermistors, the TP probe supports the multi-stage charging algorithms of Phase Three technology—bulk, absorption, and float stages all benefit from temperature-aware adjustments, reducing sulfation and gassing risks.
Batteries charge most effectively at around 77°F (25°C). Deviate too far, and efficiency drops: heat accelerates electrolyte breakdown, while cold slows chemical reactions. The TP probe acts as the charger's "sixth sense," relaying live data to dial in the ideal voltage curve.
For example, on a sweltering summer day docking in Florida, it signals the charger to lower output by up to 3% per degree above 77°F. In chilly Pacific Northwest mornings, it boosts voltage accordingly. This isn't just theory—users report 20-30% longer battery life in demanding setups.
Installation is straightforward: secure the probe to the battery case (negative terminal area for best readings), route the cable away from heat sources, and connect to the charger's dedicated port. Use zip ties or adhesive mounts for a clean, vibration-resistant setup. No soldering or special tools required.
Maintenance is minimal—periodically inspect the cable for chafing and ensure the sensing tip stays clean and dry. In high-vibration environments like off-road RVs, adding strain relief at connection points prevents wear. Pro tip: Pair it with regular battery inspections to catch issues early, like loose terminals that could skew readings.
Batteries represent a significant investment in any vessel or rig. Without compensation, premature failure wastes money and strands you mid-journey. The Newmar TP probe pays for itself through fewer replacements, reduced energy waste, and reliable power when you need it most. Boat captains and full-time RVers swear by it for peace of mind, turning variable conditions into consistent performance.
The TP probe is designed exclusively for Newmar Phase Three chargers including PT-32-30, PT-24-45F, and PT-24-95F models. Other Newmar chargers use the TCS-12/24 sensor.
It comes with a durable 25-foot cable, providing ample reach for most battery bank installations in marine or RV setups.
Temperature compensation adjusts charging voltage based on battery temperature, preventing overcharge in heat or undercharge in cold, which optimizes performance and extends battery life.
Attach the probe to the battery case near the negative terminal, route the cable securely, and plug into the charger's temperature sensor port. Avoid heat sources and ensure a firm connection.
The TP is specific to PT-32-30, PT-24-45F, and PT-24-95F models for precise Phase Three compensation, while TCS-12/24 serves other Newmar chargers with different voltage requirements.
Yes, it automatically reduces charging voltage in high temperatures, minimizing gassing, sulfation, and heat-related degradation for longer-lasting batteries.
Absolutely—its rugged build handles moisture, vibrations, and temperature swings common in boating and overland adventures.
The TP Temperature Compensation Probe is designed exclusively for use with the following NEWMAR Phase Three charger models: PT-32-30, PT-24-45F, PT-24-95F. (All other models use temp sensor model TCS-12/24.)
Ships within 48 hours · Estimated delivery Sep 20 - Sep 25
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order